3. WIRING
2) Connection
Insert the core of the cable into the opening and tighten the screw with a flat-blade screwdriver
so that the cable does not come off. (Tightening torque: 0.5 to 0.6N m) Before inserting the cable
into the opening, make sure that the screw of the terminal is fully loose.
When using a cable of 1.5mm
Cable Size
2
[mm
]
AWG
For 1 cable
Al0.25-6YE
0.25
24
Al0.25-8YE
Al0.5-6WH
0.5
20
Al0.5-8WH
Al0.75-6GY
0.75
18
Al0.75-8GY
Al1-6RD
1
18
Al1-8RD
Al1.5-6BK
1.5
16
Al1.5-8BK
Al2.5-8BU
2.5
14
Al2.5-8BU-1000
or less, two cables may be inserted into one opening.
2
To loosen.
To tighten.
Bar Terminal Type
For 2 cables
Al-TWIN2 0.75-8GY
Al-TWIN2 0.75-10GY
Al-TWIN2 1-8RD
Al-TWIN2 1-10RD
Al-TWIN2 1.5-8BK
Al-TWIN2 1.5-12BK
Al-TWIN2 2.5-10BU
Al-TWIN2 2.5-13BU
Flat-blade screwdriver
Tip thickness 0.4 to 0.6mm
Overall width 2.5 to 3.5mm
Cable
Opening
Control circuit terminal block
3 - 4
Crimping tool
CRIMPFOX-UD6