2. OPERATION
2 - 4 Parameters
(1) Parameter list
Change the parameter settings as required when using the regenerative option or when adjusting the
gains, for example.
Set the parameter values with the servo system controller or the personal computer which uses the
set-up software MRZJW3-SETUP41E or later.
When the servo system controller is connected, all parameter settings are the values set with the servo
system controller and the values set on the servo amplifier side are invalid.
When using the set-up software to change the adjustment/extension parameter settings, set 000E in
parameter No. 40.
When changing the parameter settings from the servo system controller, the parameter No. 40 value
need not be set. Among the parameters given in this section, some may not be set to some servo
system controllers.
Parameter No. 40 Setting
Reference/Write Using Servo
Setting
0000
(Initial value)
000A
000E
The initial values of the manufacturer setting parameters must not be changed.
For the parameters whose codes are marked *, set their values, switch power off once, then switch it
on again to make them valid.
Reference/Write Using Set-Up
System Controller
No.1 to 39
No.1 to 39
No.1 to 39
Software
No.1 to 11 40
No.40
No.1 to 40
2 - 8