6. OPTION AND AUXILIARY EQUIPMENT
b. For HC-SF/HC-RF
When fabricating an encoder cable, fabricate it as shown below:
MR-JHSCBL2M-L
MR-JHSCBL5M-L
MR-JHSCBL2M-H
MR-JHSCBL5M-H
Servo amplifier side
P5
19
LG
11
P5
20
LG
12
MR
7
MRR
17
P5
18
LG
2
BAT
9
LG
1
SD
Plate
AWG24 used
(For less than 10m)
In addition to the above, the customer may also fabricate the cable of the following length:
Encoder side
Servo amplifier side
S
P5
19
LG
11
P5
20
R
LG
12
C
P5
18
D
LG
2
F
MR
7
G
MRR
17
N
BAT
9
LG
1
SD
Plate
For use of AWG28 (5m or less)
Servo amplifier side
P5
19
LG
11
P5
20
LG
12
MR
7
MRR
17
P5
18
LG
2
BAT
9
LG
1
SD
Plate
MR-JHSCBL10M-L
to
MR-JHSCBL50M-L
Encoder side
S
R
C
D
F
G
N
AWG22 used
(For 10 to 50m)
Encoder side
S
R
C
D
F
G
N
6 - 9
MR-JHSCBL10M-H
to
MR-JHSCBL50M-H
Servo amplifier side
P5
19
LG
11
P5
20
LG
12
P5
18
LG
2
MR
7
MRR
17
BAT
9
LG
1
SD
Plate
AWG24 used
(For 10 to 50m)
Encoder side
S
R
C
D
F
G
N