2. OPERATION
(2) Configuration
Configuration should be as in Section 2-1 or Section 6-1-3. Always install an external emergency stop
switch to enable a stop at occurrence of an alarm.
(3) Operation procedure
Test Operation Mode
Jog operation
Positioning operation
Programmed
operation
DO forced output
Motor-less operation
Operation Procedure
1) Switch power off.
2) Set CS1 to F.
When CS1 is set to the axis number and
operation is performed by the servo
system controller, the test operation
mode screen is displayed on the personal
computer, but no function is performed.
3) Switch servo amplifier power on.
When initialization is over, the display
shows the following screen:
Decimal point flickers.
4) Perform operation with the personal
computer.
1) Switch off the servo amplifier.
2) Perform motor-less operation with the
personal computer.
The display shows the following screen:
Decimal point flickers.
Connection with Servo System Controller
2 - 18
Not required
Required