1. INTRODUCTION
Name/Application
Battery holder
Contains the battery for absolute position data
backup.
Battery connector (CON1)
Used to connect the battery for absolute position
data backup.
Display
The four-digit, seven-segment LED shows the servo
status and alarm number.
Axis select switch (CS1)
CS1
Used to set the axis number of
8
the servo amplifier.
Bus cable connector (CN1A)
Used to connect the servo system controller or preceding axis
servo amplifier.
Bus cable connector (CN1B)
Used to connect the subsequent axis servo amplifier or
termination connector (MR-A-TM).
Communication connector (CN3)
Used to connect a personal computer or output
analog monitor.
Name plate
Charge lamp
Lit to indicate that the main circuit is charged. While
this lamp is lit, do not reconnect the cables.
Encoder connector (CN2)
Connector for connection of the servo motor encoder
Control circuit terminal block (TE2)
Used to connect the control circuit power supply and
regenerative brake option.Control circuit terminal
Main circuit terminal block (TE1)
Used to connect the input power supply and servo
motor.
Protective earth (PE) terminal (
Ground terminal.
1 - 11
)
Refer To
Chapter 5(5)
Chapter 5(5)
Section 6-2-8
Section 2-3
Section 3-1-4
Section 3-1-2
Section 3-1-2
Section 3-1-2
Section 6-1-4
Section 1-1
Section 3-1-2
Section 3-1-1
Section 3-1-1
Section 3-4