Setting Parameters Required For Communications; Parameter List - Mitsubishi Electric QJ71E71-100 User Manual

Q corresponding ethernet interface module
Table of Contents

Advertisement

7.1

Setting Parameters Required for Communications

This section describes how to set parameters to communicate between the E71 and connected devices.
7.1.1

Parameter list

The following table lists parameters set through a programming tool.
Item
Basic setting
Operation Setting
Initial Setting
Open Setting
Router Relay Parameter
Station No. <-> IP Information
Network
FTP Parameters
Parameter
E-mail Setting
Interrupt Settings
Redundant settings
Routing Parameters
Group Settings
Valid Module During Other Station
Access
Predefined Protocol Support Function
Remote Password
82
Network Type
Start I/O No.
Configure settings to use the E71 as a network
Network No.
module.
Station No.
Mode
Configure the settings, such as an IP address, to
connect the E71 to Ethernet.
Set a data communication timer value.
Configure connection settings.
Configure settings to communicate with connected
devices on Ethernet via a router and a gateway.
Configure settings (e.g. network number and
station number) to communicate with other network
modules.
Configure the settings of the file transfer (FTP)
function.
Configure the settings of the e-mail function and the
automatic notification function.
Set the control number (SI) on the E71 side to
request an interrupt to the CPU module.
Configure settings to use the E71 on the main base
unit in a redundant system.
Set the communication path to communicate with a
station having a different network number.
When two communication paths are configured
between the connected device and the E71 on the
main base unit in a redundant system, configure
settings to disable system switching even if an error
occurs in either communication path.
Select a relay module when an access request with
no network number specified is issued from
another station.
The connected device side protocol can be easily
selected, or created/edited from the Predefined
Protocol Library of GX Works2.
Select the connection protected by a remote
password.
Description
Reference
Page 83, Section 7.1.2
Page 84, Section 7.1.3
Page 353, Appendix 4.1
Page 86, Section 7.1.4,
Parameter setting of each
function
MELSEC-Q/L Ethernet
Interface Module User's
Manual (Application)
Page 149, Section 12.5.1
Page 220, Section 14.7.3
MELSEC-Q/L Ethernet
Interface Module User's
Manual (Application)
QnPRHCPU User's
Manual (Redundant
System)
-
Page 111, CHAPTER 11
Page 200, Section 14.4