Udp/Ip Communications; Communication Process - Mitsubishi Electric QJ71E71-100 User Manual

Q corresponding ethernet interface module
Table of Contents

Advertisement

7.3

UDP/IP Communications

This section describes UDP/IP communications. In UDP/IP communications, the system does not establish a
connection and does not check whether each data has arrived at the destination normally, thereby reducing the load
on the line. However, UDP/IP communications do not guarantee data reliability as the TCP/IP communications do.
7.3.1

Communication process

Unlike TCP/IP communications, UDP/IP communications do not require connections to be established with connected
devices.
The server requests
data reception and
reads the received data.
After the connected device sends a close request to the E71, wait for 500ms or more before performing an open process
again.
96
Server
E71
Open
Receive process (reading)
Data sending request
Close
Client
Connected device
Open
Data sending
Data sending request
Data sending
Receive process (reading)
Close
The client opens
the port.
The client specifies
the destination and
sends data to it.
The client performs
the close process.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71e71-b5Qj71e71-b2

Table of Contents