Available Command List - Mitsubishi Electric QJ71E71-100 User Manual

Q corresponding ethernet interface module
Table of Contents

Advertisement

10.5

Available command list

The following table lists the commands that can be executed from a connected device to the E71.
The  part in the Subcommand column varies depending on the specified device.
For details on each command, refer to the following.
SLMP Reference Manual
Item
Type
Operation
Read
Write
Read Random
Device
Write Random
Entry Monitor Device
Execute Monitor
Read Block
Write Block
Read
Memory
Write
Read
Extend Unit
Write
Remote Run
Remote Stop
Remote Pause
Remote
Remote Latch Clear
Control
Remote Reset
Read Type Name
Lock
Remote
Password
Unlock
Command
Subcommand
001
0401
000
001
1401
000
0403
000
001
1402
000
0801
000
0802
0000
0406
000
1406
000
0613
0000
1613
0000
0601
0000
1601
0000
1001
0000
1002
0000
1003
0000
1005
0000
1006
0000
0101
0000
1631
0000
1630
0000
CHAPTER 10 SLMP COMMUNICATIONS
Description
Reads values in 1-point units from bit devices (consecutive device
numbers).
• Reads values in 16-point units from bit devices (consecutive device
numbers).
• Reads values in 1-word units from word devices (consecutive device
numbers).
Writes values to bit devices (consecutive device numbers) in 1-point units.
• Writes values to bit devices (consecutive device numbers) in 16-point
units.
• Writes values to word devices (consecutive device numbers) in 1-word
units.
Specifies a device number to read the device value. Discrete device
numbers can be used.
• Reads bit devices in 16- or 32-point units.
• Reads word devices in 1- or 2-word units.
Specifies a device number in 1-point units to write a value to a bit device.
Discrete device numbers can be used.
• Specifies a device number in 16-point units to write a value to a bit
device. Discrete device numbers can be used.
• Specifies a device number in 1- or 2-word units to write a value to a word
device. Discrete device numbers can be used.
Registers a device to be read by Execute Monitor (command: 0802).
Reads the value of the device registered by Entry Monitor Device
(command: 0801).
Specifies n points (1 point: 16 bits) of word or bit devices as one block, and
reads multiple blocks of data. Discrete device numbers can be used.
Specifies n points (1 point: 16 bits) of word or bit devices as one block, and
writes multiple blocks of data. Discrete device numbers can be used.
Reads buffer memory data of the E71.
Writes data to the buffer memory of the E71.
Reads buffer memory data of the intelligent function module.
Writes data to the buffer memory of the intelligent function module.
Executes remote RUN to the CPU module where an E71 is mounted.
Executes remote STOP to the CPU module where an E71 is mounted.
Executes remote PAUSE to the CPU module where an E71 is mounted.
Executes remote latch clear to the CPU module where an E71 is mounted.
Executes remote RESET to the CPU module where an E71 is mounted.
Reads the model name and code of the CPU module where an E71 is
mounted.
Specifies the remote password to disable the communication with other
devices. (The locked state is activated from the unlocked state.)
Specifies the remote password to enable communication with other
devices. (The unlocked state is activated from the locked state.)
10
109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71e71-b5Qj71e71-b2

Table of Contents