Gp.ecprtcl - Mitsubishi Electric QJ71E71-100 User Manual

Q corresponding ethernet interface module
Table of Contents

Advertisement

15.7

GP.ECPRTCL

This instruction executes the protocols registered in the flash ROM of the E71 using the predefined protocol support
function of GX Works2.
GP.ECPRTCL
Internal device
*1
Setting data
(system, user)
Bit
n1
n2
(S)
(D)
*1
The file registers set for each local device and program cannot be used.
(1) Setting data
Setting data
Un
n1
n2
(S)
(D)
Command
Link direct
File
deviceJ\
register
Word
Bit
Description
Start I/O number of the E71 (00 to FE
of the three-digit I/O number)
Connection number (1 to 16)
Number of consecutive protocol executions (1 to 8)
Start number of the device that stores control data
The start number of the bit device in the own station that
turns on for one scan upon completion of the instruction.
(D)+1 also turns on if the instruction ends abnormally.
CHAPTER 15 DEDICATED INSTRUCTIONS
GP.ECPRTCL
Un
n1
Available device
Intelligent
function module
device
Word
U\G
-
-
-
-
: The first two digits
H
User/system
n2
(S)
(D)
Index
Constant
register
Others
Zn
K, H
$
-
-
-
-
-
-
Set by
Data type
BIN 16-bit
BIN 16-bit
User
Device name
BIN 16-bit
Device name
Device name
System
Bit
-
-
15
-
-
247

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71e71-b5Qj71e71-b2

Table of Contents