Lvps Assy Mcu Pcb - Star Micronics LS-5 SERIES Technical Manual

Table of Contents

Advertisement

MAINTENANCE GUIDE
5-2-1. LVPS Assy
LVPS ASSY
PL 6.1
RELAY
FG
INTER-
LOCK
SWITCH
P/J2
1
2
Signal line name
5VDC-LD
VS
TEMP.
*1: Short prevention of power voltage output from LVPS assy
5VDC-LD
5VDC
24VDC
*2: Stopping output by no-load condition of LVPS assy
When power is turned ON while making LVPS assy no-load by removing the connector (P/J11) on MCU PCB,
output decreases after a little while (about 1 minute), and entire output stops.
Turn power OFF, connect the connector (P/J11) to provide load, and, about 5 minutes later, turn power ON again,
and output restores.
MCU PCB
HEATER ROD ON(L) 4.2VDC
SG
VS
SG
5VDC-LD
5VDC
SG
RTN
RTN
24VDC
24VDC
24VDC
TEMP.
SG
P101
LD power voltage of LD assy of ROS assy
Voltage drop signal: Outputs 5V DC when power is OFF.
Data of temp. sensor assy's thermistor
Output status
5VDC-LD
5VDC
A
B
B
A
A
P/J11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
4
1
Reference
: Output continues during shorting.
: Output stops during shorting.
24VDC
A: Automatic restore after release of
B: Output restores by turning power OFF
B
A
– 66 –
MCU PCB
PL 6.4
P15
8
P18
3
shorting
after release of shorting and by turn-
ing power ON again 2 or 3 minutes
later.

Advertisement

Table of Contents
loading