TROUBLESHOOTING

3-14. Faulty Pick Up Solenoid

Step
1
Check parts with different specifications for problems with
usage, defective installation, breakage, deformation, and adhe-
sion of grime or foreign matter.
• Main parts to be checked:
(1) Pick up solenoid, (2) MCU PCB, (3) LVPS assy
2
(Check power supply of pick up solenoid) *1
Is 24 VDC being supplied between P/J17-1PIN
2PIN?
3
(Check pick up solenoid ON signal)
Is there conductivity at approximately 120 Ω between J17-
1PIN
J17-2PIN?
4
(Check pick up solenoid) *1
Is 24 VDC being supplied between P/J17-2PIN
2PIN?
5
(Check harness assy solenoid)
Is there conductivity between J17
*1: Check with the connector (P/J111) disconnected from the HVPS.
Check
P301
– 108 –
Measure
YES
To step 2
To step 3
P/J11-
To step 4
Replace MCU
PCB.
P/J11-
Replace pick up
solenoid.
NO
Replace or
reinstall.
To section 3-2
Replace pick up
solenoid.
To step 5
Replace harness
assy solenoid.