Faulty Hvps Cr (Cd); Faulty Hvps Db - Star Micronics LS-5 SERIES Technical Manual

Table of Contents

Advertisement

TROUBLESHOOTING

3-18. Faulty HVPS CR (CD)

Step
1
Check parts with different specifications for problems with
usage, defective installation, breakage, deformation, and adhe-
sion of grime or foreign matter.
• Main parts to be checked:
(1) HVPS, (2) MCU PCB, (3) Earth plate assy
(4) Harness assy HVPS, (5) LVPS assy
2
(Check power supply of HVPS)
Is 24 VDC being supplied between P15-7PIN
3
(Check earth plate assy)
Is there conductivity between the CR terminal (plate spring) of
the earth plate assy and the corresponding terminal (J CR) on
the harness?
4
(Check harness assy HVPS)
Is there conductivity between J15
5
(Check replacement of MCU PCB)
Does the problem occur after the MCU PCB has been replaced
with a normal one?

3-19. Faulty HVPS DB

Step
1
Check parts with different specifications for problems with
usage, defective installation, breakage, deformation, and adhe-
sion of grime or foreign matter.
• Main parts to be checked:
(1) HVPS, (2) MCU PCB, (3) Earth plate assy
(4) Harness assy HVPS, (5) LVPS assy
2
(Check power supply of HVPS)
Is 24 VDC being supplied between P15-7PIN
3
(Check earth plate assy)
Is there conductivity between the DB terminal (plate spring) of
the earth plate assy and the corresponding terminal (J DB-
2PIN) on the harness?
4
(Check harness assy HVPS)
Is there conductivity between J15
5
(Check replacement of MCU PCB)
Does the problem occur after the MCU PCB has been replaced
with a normal one?
Check
P15-1PIN?
J111?
Check
P15-1PIN?
J111?
– 112 –
Measure
YES
Replace or
To step 2
reinstall.
To section 3-2
To step 3
To step 4
Replace earth
plate assy.
To step 5
Replace harness
assy HVPS.
Replace HVPS.
Processing
completed.
Measure
YES
Replace or
To step 2
reinstall.
To section 3-2
To step 3
To step 4
Replace earth
plate assy.
Replace harness
To step 5
assy HVPS.
Processing
Replace HVPS.
completed.
NO
NO

Advertisement

Table of Contents
loading

Table of Contents