REPLACEMENT AND ADJUSTMENTS OF PARTS

3-9. Inlet Chute Assembly

(1)
Open the front cover assembly [1].
(2)
Remove the following units:
• Inlet chute assembly [2]
• Connector (P/J120) [3]
• Screw [4]
Pressing down on the pick up roll assembly [5],
remove the inlet chute assembly [2], being careful
not to touch the BTR surface of the BTR assembly
[6].
Caution when assembling:
Line up the positioning boss [7] of the pick up roll assembly
[5] with the positioning groove [8] of the inlet chute
assembly [2], and attach the inlet chute assembly [2].
Make sure the inlet chute assembly [2] is positioned in front
of the inlet spring, and, being careful not to let the mylar of
the lower chute assembly get caught between the other
parts, attach the inlet chute assembly [2] so that the mylar
is positioned upwards of the inlet chute assembly [2] when
the front cover assembly [1] is open.

3-10. Regi. Sensor

(1)
Open the front cover assembly.
(2)
Remove the following units:
• Inlet chute assembly [1] (according to the proce-
dure described in section 3-9)
• Regi. sensor [2]