MAINTENANCE GUIDE
↔
5-2-3. MCU PCB
ROS Assy
MCU PCB
PL 6.4
P/J12
–
1
–
2
–
3
–
4
–
5
P15
–
6
9
–
–
7
–
8
–
9
–
10
–
11
–
12
–
13
P/J19
–
1
–
2
–
3
Signal line name
DATA
MO
VL2, VL1
5VDC-LD
SPI 2, SPI 1
SOS
DATA
⊃
5VDC
⊃
MO
⊃
VL2
⊃
VL1
⊃
SG
⊃
5VDC-LD
⊃
SPI 2
⊃
SPI 1
⊃
⊃
SG
SCANNER MOTER ON(L) 4.1VDC
⊃
RTN
⊃
24VDC
⊃
SG
⊃
SOS
⊃
5VDC
⊃
A signal to cause emission of the LD from MCU PCB to LD assy
(LD ON(L) 3.7 V DC)
Monitoring of output to LD based on data (for adjusting LD power)
Adjusts LD power.
LD power voltage of ROS assy's LD
Controls scanner motor revolution. SPI 1="H", SPI 2="L" for a resolution of 300 dpi
Start reference signal for scanning by ROS assy's scanner motor based on a laser
beam entering into SOS sensor
– 68 –
P/J112
⊃
–
7
⊃
–
6
⊃
–
5
⊃
–
4
⊃
–
3
⊃
–
2
⊃
–
1
SCANNER ASSY
P/J114
⊃
–
6
⊃
–
5
⊃
–
4
⊃
–
3
⊃
–
2
⊃
–
1
P/J113
⊃
–
3
⊃
–
2
⊃
–
1
Reference
ROS ASSY
PL 5.2
LD ASSY
SOS PCB