Cru Actuator Assembly; Ros Assembly - Star Micronics LS-5 SERIES Technical Manual

Table of Contents

Advertisement

REPLACEMENT AND ADJUSTMENTS OF PARTS

5-3. CRU Actuator Assembly

(1)
Remove the following units:
• Screw [1] and CRU sensor PCB [2] (according to
the procedure described in section 5-2)
• CRU actuator assembly [3]
• CRU actuator spring [4]

5-4. ROS Assembly

(1)
Remove the following units:
• Electrical box cover (according to the procedure
described in section 5-7)
• Ten connectors (P/J11 to P/J19) of the MCU PCB
(according to the procedure described in section
5-9)
• Six connectors (P/J111, P/J CR, P/J DB, P/J TR,
P/J RTN, P/J PTN) of the HVPS (according to the
procedure described in section 5-10)
• Screw securing the wire assembly front and the
ground wire to the LVPS assembly
• Gear double L (according to the procedure
described in section 3-2)
• Gear double R (according to the procedure
described in section 3-3)
• Earth plate assembly (according to the procedure
described in section 5-8)
• Cable cap (according to the procedure described
in section 3-6)
• Front cover assembly (according to the procedure
described in section 3-6)
• Electrical box base with MCU PCB (according to
the procedure described in section 5-11)
• HVPS (according to the procedure described in
section 5-10)
• LVPS (according to the procedure described in
section 5-11)
• Drive assembly (according to the procedure
described in section 5-1)
• CRU actuator assembly (according to the proce-
dure described in section 5-3)
• Six screws [1]
• Front earth spring [2]
• Connector (P/J112) [3] and connector (P/J114) [4]
• Connector (P/J113) [5]
• ROS assembly [6]
– 46 –