13.3 DEVICE OPERATION MODE SPECIFIED AT THE CE PIN

The CE pin controls the following items according to the level and positive-going edge of its input signal.
(1) Whether to enable or disable the clock stop instruction
(2) Whether to reset the device
Sections 13.3.1 and 13.3.2 explain the above items, respectively.
13.3.1 Controlling Whether to Enable or Disable the Clock Stop Instruction
The clock stop instruction, STOP s, is effective only when the CE pin is at a low level.
If the STOP s instruction is executed when the CE pin is at a high level, it is treated as a no-operation (NOP)
instruction.
13.3.2 Resetting the Device
Driving the CE pin from a low to a high can reset the device (CE reset).
There is another type of reset, which is a power-on reset. It occurs when supply voltage V
See Chapter 14 for details.
13.3.3 Signal Inputs to the CE Pin
The CE pin does not accept a high or low level with a duration of less than 187.5 s to prevent malfunction
due to noise.
The input level of a signal supplied to the CE pin is checked using the CE flag in the control register (bit
b
at address 07H).
0
Fig. 13-2 shows the relationship between the input signal and CE flag.
Fig. 13-2 Relationship Between the Input Signal and CE Flag
CE pin
CE flag
Less than 187.5 s
STOP instruction disabled (NOP)
187.5 s
Less than 187.5 s
STOP instruction enabled
187.5 s
CE reset
STOP instruction disabled (NOP);
a CE reset occurs next time
the timer carry FF is set.
PD17062
is turned on.