RAP 04: Bail Homing Error

START.
Manually rotate the bail open gear counterclockwise.
Does it rotate smoothly?
NO
Remove all obstructions from the bail motor gear, idle gear, and bail open gear.
Check the meshing of each of the following. Replace defective items.
Bail Motor Gear
Idle Gear
Bail Open Gear
YES
Is the cable to CN4 on the main logic board connected correctly?
NO
Connect it correctly.
YES
Are the cables to CN2 and CN3 on the sensor board connected correctly?
NO
Connect them correctly.
YES
Is there dirt or dust on any of the sensors on the sensor board?
YES
Clean the sensors.
NO
Is the bail arm lever damaged?
YES
NO
Is the problem resolved?
YES
NO
Is the problem resolved?
Failure Analysis
Replace the bail arm lever.
Replace the main logic board.
End of procedure.
Replace the sensor board.
YES
End of procedure.
NO
Replace the bail motor.
Is the problem resolved?
YES
End of procedure.
NO
Contact Technical Support.