Registration; Scanner Calibration - Lexmark MS911 Service Manual

Hide thumbs Also See for MS911:
Table of Contents

Advertisement

REGISTRATION

This menu allows you to perform the following:
1
Adjust the top and left margin values of the installed trays.
2
View how the change in margin values affect the overall registration of the printer.
To set the registration:
1
Print a Quick Test page.
a
Enter the Diagnostics Menu, and then navigate to:
REGISTRATION > Quick Test
b
Retain this page to determine the changes you need for the margin settings. The alignment diamonds in the
margins should touch the margins of the page.
2
Change the value of the margin settings.
Margin
Top Margin
Left Margin

SCANNER CALIBRATION

Scanner Calibration
This test calibrates the black and white values for the ADF and flatbed. Use the following values to manually adjust a
replacement scanner.
Menu items
Flatbed Black
ADF Front Black
ADF Back Black
Flatbed White
ADF Front White
ADF Back White
* The default value is 0.
To adjust a calibration value, do the following steps:
1
Enter the Diagnostics Menu, and then select Scanner Calibration.
2
Select a calibration value to adjust.
3
To view the result for an ADF front adjustment, place a test page image side up and touch Copy Quick Test. Compare
the results to the original, and adjust if necessary.
4
To view the result for an ADF back adjustment, place a test page image side down and touch Copy Quick Test.
Compare the results to the original, and adjust if necessary.
Value
Description
-15 to +15
Moves the top margin of the installed trays either up or down
‑15 to +15
Moves the left margin of the tray to the right or left
Values
‑10 to 10*
‑10 to 10*
‑10 to 10*
‑10 to 10*
‑10 to 10*
‑10 to 10*