32Y Errors; 32Y Error Messages - Lexmark MS911 Service Manual

Hide thumbs Also See for MS911:
Table of Contents

Advertisement

Action
Step 13
a
Test the sensor.
Enter the Diagnostics menu, and then navigate to:
SENSOR TESTS > Staple Finisher > Elevator bin stack height or Elevator
bin level
b
Toggle the sensor.
Does the sensor status change while toggling the sensor?
Step 14
Replace the sensor. See
"Staple finisher bin stack height assembly
sensors removal" on page
Does the problem remain?
Step 15
a
Reseat the interface cable on the staple finisher controller board and
printer.
b
Reseat the junction connector on the cable.
c
Check the cable for damage, and replace if necessary.
Does the problem remain?
Step 16
a
Reseat all the cables on the staple finisher controller board.
b
Reset the printer.
Does the problem remain?
Step 17
Replace the controller board. See
removal" on page
244.
Does the problem remain?

32y errors

32y error messages

Error code
Description
321.07
The motor (SHPF feed) failed.
323.07
The motor (SHPF compiler feed roller release) failed. See
324.07
The motor (SHPF paddle) failed.
234.
"Staple finisher controller board
Diagnostic information
Yes
Go to step 14.
Go to step 15.
Go to step 16.
Go to step 17.
Contact the next level
of support.
Action
See
"SHPF paper feed failure service check" on
page
109..
"Motor (SHPF compiler feed roller release)
failure service check" on page
See
"Motor (SHPF paddle) failure service check"
on page
114.
108
4021, 7421
No
The problem is solved.
The problem is solved.
The problem is solved.
The problem is solved.
The problem is solved.
111.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm91x5Mx91x

Table of Contents