Chapter 4: Maintenance
Maintenance Schedule
Procedure
Clean imaging guides
Clean paper path
Replace separator
module and separator
module tires
Replace pre-separation
pad
Replace feed module
and feed module tires
Replace imaging guides
74
Interval
Daily
Daily
Every 200,000
documents scanned
Every 250,000
documents scanned
Every 500,000
documents scanned
Only when guides are
scratched or damaged
What to Use
Use staticide wipe, (part
number 830 9783) -- slightly
damp. Wipe with a dry
staticide wipe before
scanning. If dust is on the
underside of the imaging
guide, remove the imaging
guide and clean. WIPE
AWAY FROM THE
PATCH to avoid leaving
dust or debris on the patch.
Use emulsiclean wipe, (part
number 137 4966) in
transport area and on red
and white rollers. Allow to
air dry.
CAUTION:
DO NOT USE
THE EMULSICLEAN
WIPE ON THE
FOAM TIRES.
Use parts from feeder
consumables kit, (part
number 880 9485).
Use parts from feeder
consumables kit, (part
number 880 9485).
Use parts from feeder
consumables kit, (part
number 880 9485).
Use upper imaging guide
(part number 169 5790) or
lower imaging guide (part
number 857 5292).