Chapter 4: Maintenance
Replacing the Imaging Guides
96
8.
Align the new upper imaging guide in the guide track
and slowly push it in making sure that you can see the
solid black side of the patch.
9.
Realign the upper imaging guide bracket and secure
with the screw.
10.
Reinstall the side door.
11.
Lower the scanner cover and press it down firmly
until it latches into place.
Patch
Bracket
Scantron iNSIGHT 30 Scanner