Chapter 6: Troubleshooting
The Scan Validation Tool Diagnostics Window
128

Diagnostics - General Tab

The General tab allows you to perform a scanner test and
displays the scanner time.
Scanner: similar to, but more extensive than, a power-
Tests
on self test. Selecting this will immediately put the
device through a series of checks to determine that all
the scanner hardware is working.
Count only: counts the number of documents enter-
ing the scanner without actually sending the images to
the scanning application. This test is performed during
any scan session in which this option is turned on.
This test is automatically turned off when the
NOTE.
scanning application disconnects from the scanner.
Printer: tests the functionality of the printer (e.g.,
whether all ink jets are working). This test is per-
formed during any scan session in which this option is
turned on.
NOTE:
This test is automatically turned off when the
scanning application disconnects from the scanner.