Chapter 4: Maintenance
Replacing the Imaging Guides
Replacing the Imaging Guides
94
Replacing the Upper Imaging Guide
1.
Open the side door on the right side of the scanner to
gain access to the upper imaging guide. Push down on
the tab, remove the side door and set it aside.
2.
Remove any dust or debris from the guide track area.
Clean the area thoroughly with a staticide wipe (part
number 830 9783) to prevent any debris from falling
into the scanner when you remove the imaging guide.
3.
Using a Phillips head screwdriver, loosen the screw
securing the upper imaging guide bracket and slide the
bracket over.
Tab
Side Door
Guide Track
Phillips
Screwdriver