ESI IP 200 Installation Manual page 41

Ip series
Table of Contents

Advertisement

IP Series Installation Manual
Function 2132: Line Build Out
Use the arrow keys to select a value of 1–8. Press # to confirm. Default: 1.
The level programmed depends on the application (CSU or DSX-1) indicated in the following table:
Level
1
2
3
4
5
6
7
8
Function 2133: CSU Emulation
Use the scroll keys to toggle between enabled and disabled. Default: Off. If there is no external
CSU, the CSU Emulation setting should be set to On but the remaining options should be left at the
default setting of On. When CSU emulation is enabled, the following test options will be available
and should be used only at the request of the carrier:
Test option*
Description
ATT PRF
Loopback test per AT&T spec 62411 for performance assessments,
sent to the carrier on ESF trunks only.
ANSI PRM
Loopback test per ANSI spec T1.403 for performance assessments,
sent to the carrier on ESF trunks only.
PLB
(Payload loopback.) Accepts signal from the carrier at the chip level,
puts it through the framer (de-frames and re-frames signal with data
staying the same) and sends it back to the carrier. Used to determine
whether the chip itself is functioning correctly.
LLB
(Line loopback.) Sends the signal back right at the point it enters the
chip before it enters the framer. Helps determine whether the line
itself is good.
NET LLB
(Network loopback.) Lets the carrier put the DLC's CSU into any of the
loopback modes.
* Test options available only when CSU emulation is set to On.
Warning:
The default setting is Off for those systems using an external CSU. If there is no
external CSU, the CSU Emulation setting should be set to On but the remaining
options should be left at the default of Off. Use these other settings ONLY at the
request of your carrier or the phone system manufacturer for testing purposes.
Function 2134: Switch protocol selection
Use the scroll keys to select from the four switch options for your carrier.
• Nortel – DMS100
• AT&T/Lucent – 5ESS
• National/NI2 - Default
• Siemens - EWSD
Note: Most switches can emulate the various protocols. Please be sure to base your selection on
the protocol actually being used rather than the identity of the switch manufacturer. For ex-
ample, your central office could have a Nortel DMS100 switch but have the span configured
as NI2; in this case, you should choose the default setting of National/NI2.
CSU line build-out
0 dB
N/A
N/A
N/A
N/A
-7.5 dB
-15 dB
-22.5 dB
Function 2: CO lines
DSX-1 line build-out
0 to 133 feet
133 to 266 feet
266 to 399 feet
399 to 533 feet
533 to 655 feet
N/A
N/A
N/A
Options
On/Off
On/Off
On/Off
On/Off
On/Off
Default
Off
Off
Off
Off
Off
E.9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip 40

Table of Contents