ESI IP 200 Installation Manual page 56

Ip series
Table of Contents

Advertisement

Function 3: Extension programming
Paired IP Feature Phone/analog phone operation
For someone wishing to have an IP Feature Phone in his office and a cordless phone for roaming
the building:
1. Create a call forward key on the IP Feature Phone to forward to the cordless phone.
2. Program the call forward busy/no answer for the cordless station to the IP Feature Phone's
mailbox. The user will then have all of his messages in one location (however, he/she can re-
trieve them from either phone).
Overhead paging interface
You can connect a dry-contact overhead paging device to the system through the OH Paging inter-
face on the front of the IP PBX. The overhead paging port's access is fixed as extension 199 for
programming purposes. The user can access it by:
(a.) Dialing 1 9 9
or
(b.) Programming 199 as a programmable key
and /or including 199 in one or more page zones.
Note: DTMF can be transmitted to the overhead paging port after access, allowing for zone over-
head paging, if the paging unit supports zone paging.
1.
Ext.
Type
0
100
199
Each programming step for overhead paging is defined as follows:
1. Extension number — Enter 1 9 9 during extension programming.
2. Extension page zone assignment — List the page zones (1, 2, 3) that are to include, also, the
overhead paging port. (All page)
Example: Here is a portion of a completed Programming Worksheet (Appendix II) for
extensions. The paging port, extension 199, has been added to page zone 1.
The user then can access only the overhead pager by dialing 1 9 9 or can
page through both the overhead pager and all phones listed in page zone 1
by pressing PAGE (#) and 1 on his/her phone.
Dry contact control
The manner in which the dry contact pair is pinned out at the RJ-45 connector sets the pair as either
normally open (sending a page to the port will close the contacts) or normally closed (sending a
page to the port will open the contacts). See the "Hardware installation" section (page B.7).
F.8
Name
Operator
FP
Jane
1.
Ext.
Type
Name
100 IP PHONE
JANE
199
CO
CF day
Cf night
X100
X100
9
MB100
X105
2.
CO
Pg zn
9
1,2
IP Series Installation Manual
2.
Pg zn
1,2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip 40