Function 56: Cascade Paging Mailboxes - ESI IP 200 Installation Manual

Ip series
Table of Contents

Advertisement

IP Series Installation Manual
Function 552: Delivery/paging parameters
The sequence of programming is as follows:
1. CO line access — Enter the CO Line Group (9, 8, or 71–76) that is to be accessed for delivery.
Default: 9.
2. Maximum lines — Enter the maximum number of lines (in the selected CO line group) that the
system can access simultaneously. Make enough lines available to accommodate high notifica-
tion traffic (but be careful: if you make available all lines in the selected line group and high
notification traffic occurs, the system could tie up all lines).
Range: 1–19. Default: 1.
3. Pager dialing pause — When paging, the IP Series system will send the mailbox number to be
shown in the pager's display. To allow time for the paging service to answer, enter the pause, in
seconds, that is to occur between when the IP Series system dials the pager number and when
it then dials the mailbox number.
Range: 0–20. Default: 6.

Function 56: Cascade paging mailboxes

In addition to individual mailbox paging, the system can support up to 10 cascade paging mailboxes
(520–529). These can be assigned to anyone who requires escalating levels of paging beyond the
single level available in all user mailboxes. In this function, you program the paging numbers and
number of times each is to be paged before the next paging number is added; additionally, the
mailbox owner can program these settings. To record a greeting, press PROG/HELP * and enter the
mailbox number; then press # and follow the prompts. The default password is the mailbox number.
Press either 1 for cascade paging mailbox options or 2 for cascade paging mailbox parameters.
Cascade paging mailbox options
The user can program up to three paging numbers, of up to 24 digits each, to be paged whenever
the mailbox takes a new or urgent message. The system will page the first paging number (for the
number of times listed), then add the second paging number (for the number of times listed),
then add the third paging number and will continue to page all three pagers until the message
has been retrieved.
1.
MB
1st Number
520
2145553232
4. Press PROG/HELP * and enter the mailbox number (range: 520–529); then press # to confirm.
Note: The default password is the mailbox number.
5. Press 6 for pager number programming and press # to confirm.
6. Press 1 to enter message notification numbers.
7. Enter the first pager number — the number to be dialed (without the CO Line Group [9, 8 or
71–76]) — and press # to confirm.
8. Enter the attempts — how many times the system will page (up to 20) before adding the sec-
ond pager number. Range: 0–99. (0 turns off delivery.) Press # to confirm.
9. Enter the second pager number and press # to confirm.
10. Enter the attempts for the second pager number and press # to confirm.
11. Enter the third pager number and press # to confirm.
4.
5.
Attempts
2
Function 5: Voice mail programming
6.
7.
2nd Number
Attempts
2145554254
3
8.
3rd Number
2145555452
H.5