Document History - Hengstler eXtendo X-56 Reference Manual

Firmware: v2.00 (usb and rs-232)
Hide thumbs Also See for eXtendo X-56:
Table of Contents

Advertisement

®
eXtendo
Emulation Command Set Reference
Revision
Date
1.00
2007 Oct 5
1.01
2007 Nov 7
1.02
2007 Nov 13
1.03
2008 Jan 24
1.04
2008 June 16
1.05
2008 June 18
1.06
2008 June 27
1.07
2010 April 29
2.00
2013 Aug 15
Part No. D 684 112

Document History

Init
Status
Description
CBL
Closed Initial version
Closed Add "Printer Status Summary", bit 15: "Printer not
CBL
ready to print". "End of Page" definition of
parameter [n] revised. Add "Start Block Rotation"
and "End Block Rotation" commands.
CBL
Closed Admonition to use hardware handshaking added.
CBL
Closed Added released firmware version 1.00 to Comments
section. Modify ITF section of bar code command,
adding checksum calculation explanation. Add
known bug of ITF not calculating checksum. Add
explanation of Advanced Firmware Features and
highlight Advanced Firmware commands. Add note
that print speed will not exceed 130 mm/s
regardless of print speed setting if printer was
ordered with lower print speed. Changed parameter
[m] in 1D barcodes to be hex.
CBL
Closed Correct error in "Print Stored Image Data"; m and n
reversed. Correct error ESC!+n command; double-
height and double-width reversed. Advanced
Firmware option made standard. Change references
to firmware v1.01. Reflect corrected ITF barcode
function and remove ITF checksum calculation.
Commands Position Stamp Set, Position Stamp
Feed, and Position Stamp Retract added.
CBL
Closed Correct error in RS-232 Configuration command.
CBL
Closed Correct Code 128 error. Add known anomaly that
manual selection of Code 128 subset C does not
function correctly. Add known anomaly that
selection of bar code type [48]
Clarify print speed maximum 130 mm/sec with 12V
printhead in print speed setting command section.
CBL
Closed Correct Mod. Nr. first digit to "4". Add ® symbol to
eXtendo
Position Stamp Feed and Position Stamp Retract.
Extend Status DWORD with EEPROM Missing
flags. Add description of firmware patches. Extend
Status DWORD with three partial cut monitoring
flags. Remove limitation on barcode subtitling when
rotating barcode. Add CAN command. Add create
bitmap and bitmap body data commands.
CBL
Closed Upgrade for FW 2.00. Correct erroneous decimal
value for CR; correct PDF barcode "n" value;
expand print speed command to cover two bytes;
correct error in decimal value for End of Page;
starting stored image number corrected from "1" to
"0"; add Paper Eject command; add X-56 Feed
Unload/Reload command; add expanded 2D bar
code info; add horizontal alignment command; add
print character commands; add country codes.
Mod.Nr. 4 150813 LEV
16
causes a reset.
®
name. Correct Function description for