Esc [F1]+[01]+[0C]+[04]+[M1] - Hengstler eXtendo X-56 Reference Manual

Firmware: v2.00 (usb and rs-232)
Hide thumbs Also See for eXtendo X-56:
Table of Contents

Advertisement

®
eXtendo
Emulation Command Set Reference
2.1.52 ESC [F1]+[01]+[0C]+[04]+[m1]..[m11]
[Name]
Burn Time Correction
[Function]
This command is used to adjustments in burn time at different temperature
settings.
16
[Code]
[1B]
10
[27]
[Description]
1.
The "ESC [F1]+[01]+[0C]+[04]+[m1]..[m11]" command specifies corrections to burn time based on
ambient temperature.
2.
The variables [m1] to [m11] are 8-bit, signed integers that specify the burn time adjustment in µs.
3.
The adjustment range of [m1] to [m11] is from -125 to +125 µs.
4.
The variables [m1] to [m11] relate to the temperature as follows.
5.
The intended purpose of the Burn Time Correction is to adjust the eXtendo
response at various ambient temperatures to match different, Hengstler-approved thermal paper
types.
6.
Sample wide fonts (standard and KS5601-Korean) are provided in the driver package.
Part No. D 684 112
16
16
+ [F1]
+ [01]
+ [0C]
10
10
+ [241]
+ [01]
+ [12]
Variable
m1
m2
m3
m4
m5
m6
m7
m8
m9
m10
m11
Mod.Nr. 4 150813 LEV
Burn Time Correction
16
16
+ [04]
+ [m1]
10
10
+ [04]
+ [m1]
Temperature
-30ºC
-20ºC
-10ºC
0ºC
+10ºC
+20ºC
+30ºC
+40ºC
+50ºC
+60ºC
+70ºC
... [m11]
... [m11]
®
temperature
Page 71 of 95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extendo x-80

Table of Contents