Esc [F1]+[01]+[08]+[00]+[D1] - Hengstler eXtendo X-56 Reference Manual

Firmware: v2.00 (usb and rs-232)
Hide thumbs Also See for eXtendo X-56:
Table of Contents

Advertisement

®
eXtendo
Emulation Command Set Reference
2.1.54 ESC [F1]+[01]+[08]+[00]+[d1]...[d7] RS-232 Communication
[Name]
RS-232 communication parameter setting
[Function]
This command is used to specify the RS-232 communication parameters such as
baud rate, stop bits, data bits, parity and flow control.
16
[Code]
[1B]
10
[27]
[Description]
1.
The "ESC [F1]+[01]+[08]+[00]+[d1]...[d7]" command specifies the serial communication
parameters for RS-232 versions of the eXtendo
2.
The following serial communication parameters are specified in [d1]...[d7] as follows: baud rate in
[d1], parity on/off in [d2], parity odd/even in [d3], number of data bits in [d4], number of stop bits in
[d5], flow control in [d6] and an additional block host TX (CTS signal low) on paper out flag [d7].
3.
Parameter [d1] specifies the baud rates as follows:
10
[00]
=
4800
10
[01]
=
9600
10
[02]
=
19200
10
[03]
=
38400
10
[04]
=
57600
10
[05]
=
115200
10
[06]
=
230400 (unsupported at this time)
10
[07]
=
460800 (unsupported at this time)
Choosing an unsupported or undefined value will cause the printer to select 115200 baud.
4.
Parameter [d2] specifies the parity on/off as follows:
10
[00]
=
PARITY OFF
10
[01]
=
PARITY ON
An unsupported or undefined value will select PARITY OFF.
5.
Parameter [d3] specifies the parity even/odd as follows:
10
[00]
=
PARITY ODD
10
[01]
=
PARITY EVEN
An unsupported or undefined value will select PARITY ODD.
Parity even/odd is ignored unless parity is ON.
6.
Parameter [d4] specifies the data bits as follows:
10
[00]
=
7 DATA BITS (unsupported at this time)
10
[01]
=
8 DATA BITS
Any value for d4 will select 8 DATA BITS.
7.
Parameter [d5] specifies the stop bits as follows:
10
[00]
=
1 STOP BIT
10
[01]
=
2 STOP BITS
An unsupported or undefined value will select 1 STOP BIT.
8.
Parameter [d6] specifies the control flow as follows:
10
[00]
=
NO FLOW CONTROL (unsupported)
10
[01]
=
HARDWARE FLOW CONTROL – RTS / CTS
10
[02]
=
SOFTWARE FLOW CONTROL - XON/XOFF (unsupported at this time)
An unsupported or undefined value will select HARDWARE FLOW CONTROL – RTS / CTS.
(RTS = Ready To Send, CTS = Clear To Send)
Part No. D 684 112
16
16
+ [F1]
+ [01]
+
10
10
+ [241]
+ [01]
+
®
Mod.Nr. 4 150813 LEV
Parameter Setting
16
16
[08]
+ [00]
+
[d1]... [d7]
10
10
[08]
+ [00]
+
[d1]... [d7]
printer.
Page 73 of 95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extendo x-80

Table of Contents