Recharging Operation - Suzuki GSX-R750 Service Manual

Hide thumbs Also See for GSX-R750:
Table of Contents

Advertisement

7-42 ELECTRICAL SYSTEM

RECHARGING OPERATION

• Using the multi circuit tester, check the battery voltage. If the
voltage reading is less than the 12.0V (DC), recharge the bat-
tery with a battery charger.
#
* When recharging the battery, remove the battery from
the motorcycle.
* Do not remove the caps on the battery top while re-
charging.
Recharging time: 5A for one hour or 1.2A for 5 to 10 hours
#
Be careful not to permit the charging current to exceed
5A at any time.
• After recharging, wait for more than 30 minutes and check the
battery voltage with a multi circuit tester.
• If the battery voltage is less than the 12.5V, recharge the bat-
tery again.
• If battery voltage is still less than 12.5V, after recharging, re-
place the battery with a new one.
• When the motorcycle is not used for a long period, check the
battery every 1 month to prevent the battery discharge.