Sfp+ Direct Attach Cables For Ex Series Switches; Cable Specifications; Figure 35: Sfp+ Direct Attach Cables For Ex Series Switches - Juniper EX9214 Hardware Manual

Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

SFP+ Direct Attach Cables for EX Series Switches

Cable Specifications

Table 47: Software Support for SFP+ Passive Direct Attach Cables for EX Series Switches
Switch
EX3200 switches
EX4200-24T, EX4200-24T-DC, EX4200-24P,
EX4200-24PX, EX4200-24F, EX4200-24F-DC,
EX4200-48T, EX4200-48T-DC, EX4200-48P,
and EX4200-48PX switches
EX4200-24F-S and EX4200-48T-S switches
Copyright © 2015, Juniper Networks, Inc.
EX9200-4QS Line Card on page 52
EX9200-6QS Line Card on page 53
EX9200-40T Line Card on page 55
EX9200-40F Line Card on page 57
EX9200-40F-M Line Card on page 58
Small form-factor pluggable plus transceiver (SFP+) direct attach copper cables, also
known as Twinax cables, are suitable for in-rack connections between servers and
switches. They are suitable for short distances of up to 7 m (23 ft), making them ideal
for highly cost-effective networking connectivity within a rack and between adjacent
racks. See
Figure 35 on page

Figure 35: SFP+ Direct Attach Cables for EX Series Switches

This topic describes:
Cable Specifications on page 111
Standards Supported by These Cables on page 115
EX Series switches support SFP+ passive direct attach cables. The passive Twinax cable
is a straight cable with no active electronic components. EX Series switches support 1 m,
3 m, 5 m, and 7 m long SFP+ passive direct attach cables.
Table 47 on page 111
describes the support for SFP+ passive direct attach cable lengths
on EX Series switches for Junos OS releases.
Software Support Added
Junos OS Release 10.3
Junos OS Release 10.3
Junos OS Release 12.3R4
Chapter 8: Transceiver and Cable Specifications
111.
Cable Length
1 m (3 ft), 3 m (10 ft), 5 m (16 ft), and 7 m
(23 ft)
1 m (3 ft), 3 m (10 ft), 5 m (16 ft), and 7 m
(23 ft)
1 m (3 ft), 3 m (10 ft), 5 m (16 ft), and 7 m
(23 ft)
111