Extreme Networks Summit X150 Series Hardware Installation Manual page 401

Summit family
Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

Table 78: Summit X670 Series Switch Technical Specifications (Continued)
Safety Standards
North American Safety of ITE
European Safety of ITE
International Safety of ITE
EMI/EMC Standards
North America EMC for ITE
European EMC standards
International EMC certifications
Country-specific
Telecom Standards
IEEE 802.3 Media Access
Standards
Environmental Data
Environmental standards
Operating conditions
Summit Family Switches Hardware Installation Guide
UL 60950-1 1st Ed., Listed Device (US)
CSA 22.2 #60950-1-07 2nd Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
EN 60950-1:2006 2nd Ed. TUV-R GS
EN 60825-1:2007 (Lasers Safety)
2006/95/EC Low Voltage Directive
CB Report & Certificate per IEC 60950-1:2005 2nd Ed.,
+ National Differences
AS/NZX 60950-1 (Australia /New Zealand)
FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
EN 55022:2006+A1:2007 Class A
EN 55024:1998+A1:2001+A2:2003
Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2: 2006+A2:2009 (Harmonics)
EN 61000-3-3:2008 (Flicker)
ETSI EN 300 386: v1.4.1 (2008-04) (EMC Telecommunications)
2004/108/EC EMC Directive
CISPR 22: 2008 (Ed 6.0), Class A (International Emissions)
EN 55024:1998+A1:2001+A2:2003 Class A (International Immunity)
IEC/EN 61000-4-2:2008 Electrostatic Discharge, 8kV Contact, 15 kV Air,
Criteria A
IEC/EN 61000-4-3:2008 Radiated Immunity 10V/m, Criteria
IEC/EN 61000-4-4:2004 Transient Burst, 1 kV, Criteria A
IEC/EN 61000-4-5:2005 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC/EN 61000-4-6:2008 Conducted Immunity, 0.15-80 MHz,
10V/m unmod. RMS, Criteria A
IEC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%,
25 periods, Criteria C
VCCI Class A (Japan Emissions)
BSMI (Taiwan Emissions)
ACMA (C-Tick) (Australia Emissions)
CCC Mark (China)
KCC Mark, EMC Approval (Korea)
EN/ETSI 300 386:2008 (EMC Telecommunications)
EN/ETSI 300 019 (Environmental for Telecommunications)
MEF9 and MEF14 certified for EPL, EVPL, and ELAN
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-X
IEEE 802.3ae 10GBASE-X
IEEE 802.3ba 40GBASE-X
EN/ETSI 300 019-2-1 v2.1.2 (2000 - 2009) - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 (1999 - 09) - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 (2003 - 04) - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5G
Temperature range: 0° C to 45° C (32° F to 113° F)
Humidity: 10% to 95% relative humidity, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
Operational shock (half sine): 30 m/s
Operational random vibration: 3 to 500 Hz at 1.5 G rms
Summit X670 Series Switches
2
(3 G), 11 ms, 60 shocks
401

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents