Extreme Networks Summit X150 Series Hardware Installation Manual page 153

Summit family
Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

If you configure an alternate stacking port on a switch that has native stacking ports, the native stacking
port becomes inactive and cannot be used. When a data port becomes an alternate stacking port, it can
no longer operate as a data port.
When you connect distant nodes using alternate stacking ports, be sure to run the cables over physically
different pathways to reduce the probability a cut occurring to both links.
See
Table 50
for the ports that are available on each switch model that supports this feature. For each
switch model, the column labeled Alternate Stacking Port 1 shows the switch port that replaces native
stacking port 1, and Alternate Stacking Port 2 lists the switch port that replaces native stacking port 2.
Switch models that are not listed in the table do not support the SummitStack-V feature.
NOTE
The SummitStack-V feature is supported only on switches that are running ExtremeXOS 12.5.1 (or later).
Table 50: Alternate Stacking Ports
Switch Model
Summit X450a-24t
Summit X450a-24tDC
Summit X450a-24x
Summit X450a-24xDC
Summit X450a-24p
Summit X450e-24t
Summit X450a-48t
Summit X450a- 48tDC
Summit X450e-48p
Summit X460-24t
Summit X460-24x
Summit X460-24p
Summit X460-48t
Summit X460-48p
Summit X460-48x
Summit X480-24x
Summit X480-48t
Summit X480-48x
Summit Family Switches Hardware Installation Guide
Type or location of Native
Stacking Ports
Fixed (rear panel)
Fixed (rear panel)
SummitStack module
SummitStack-V80 module
SummitStack module
SummitStack-V80 module
SummitStack module
SummitStack-V80 module
None (VIM has only data ports)
None (no installed VIM)
VIM2-SummitStack module
VIM2-SummitStack128 module
VIM2-SummitStack-V80 module
None (VIM has only data ports)
NOTE: The Summit X480-48t or X480-48x switch must have an installed VIM2-10G4X
module to configure alternate stacking ports.
Using the SummitStack-V Feature
Alternate
Alternate
Stacking
Stacking
Location of Alternate
Port 1
Port 2
Stacking Ports
25
26
XGM2-2xf option card
XGM2-2xn option card
XGM2-2sf option card
XGM2-2bt option card
49
50
XGM2-2xf option card
XGM2-2xn option card
XGM2-2sf option card
XGM2-2bt option card
S1 (29)
S2 (30)
XGM3-2sf option card
S1 (53)
S2 (54)
XGM3-2sf option card
S1 (49)
S2 (50)
XGM3-2sf option card
S3 (29)
S4 (30)
VIM2-10G4X module
25
26
Front panel
25
26
Front panel
S3 (51)
S4 (52)
VIM2-10G4X module
153