Pattern - Paradyne Comsphere 3920Plus Installation And Operation Manual

Comsphere 392 plus series
Hide thumbs Also See for Comsphere 3920Plus:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
The message Started appears on the LCD and the Test LED lights. The port field (for example, P1
for Port 1) displays the port that is currently selected. You may see P1, P2, P3, or P4.
If OtherTestActive appears on the LCD, another test is in progress. Select Abort to clear the
current test and try again. If the Test Timeout configuration option is enabled, Test Timeout
appears at the conclusion of the display. If it is disabled, the test operates until aborted. For more
information on the Test Timeout configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the
Top-Level menu, press the

Pattern

Pattern can transmit and receive a 511 bit error rate test pattern. It can also be used with a currently
running local analog loopback or a remote digital loopback to simulate data passing through the
modem. You will need to start the local analog or remote digital loopback test before you start the
pattern test. For this test to operate properly, the modems must be online and in Synchronous or
Asynchronous Direct mode. Otherwise, the message Invalid Command appears when this test is
started (Figures 3-7 through 3-9).
Figure 3-7. Pattern Test and Local Analog Loopback Test
3-60
Test:P1:Dig Loop
Started
F1
F2
F3
key.
April 1995
key. To exit and return to the
3920-A2-GN31-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3921plus

Table of Contents