Paradyne Comsphere 3920Plus Installation And Operation Manual page 46

Comsphere 392 plus series
Hide thumbs Also See for Comsphere 3920Plus:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
Status
Message
Call Failure
Busy Signal
Delayed
Number
Dial Line in Use
Forbidden
Number
Invalid Number
Line Occupied
No Answer Tone
No Dial–DTR
No Dial–Test
No Dial Tone
No Quiet Answer
Ringback
Timeout
Trunk Busy
Wrong Call
{
The Delayed Number and Forbidden Number messages appear only in countries where the number of repeat call
attempts are restricted. The regulations vary in each country. If the number is delayed, the value of the delay
(in minutes) can be displayed by entering Directory Status (see Call Setup Branch ).
{{
The Line Occupied message appears only in countries where the Offhook Detector is enabled. The purpose of the
Offhook Detector is to detect whether the telephone associated with the modem is off-hook. It is enabled on a per
country basis, and this setting can not be changed by a command. The Offhook Detector is enabled in Austria,
Germany, and Switzerland.
3-12
Table 3-3
(2 of 3)
Top-Level Menu Status
The answering modem is busy.
As a result of failed call attempts, this number can not be called at this time.
{
Please try again later.
The modem is operating on dial networks when another call attempt is
issued.
As a result of failed call attempts, this number can not be called again.
{
The modem has dialed a telephone number not stored in a directory
location.
{{
The line is being used by the associated telephone.
The answering modem did not answer within the time limit specified by the
No Answer Timeout configuration option. The network tones (if any) could
not be interpreted by the modem.
The modem cannot dial because DTR is OFF.
The modem cannot dial because it is running a Test.
The modem has aborted the call because it cannot detect a dial tone.
The modem has detected No Quiet Answer (@) before the time-out setting
of the No Answer Disconnect configuration option.
The answering modem did not answer within the time limit specified by the
No Answer Timeout configuration option. A ringback signal was detected.
The modem is receiving a fast (trunk) busy.
The call was answered, but not by a modem. No answer tone.
April 1995