Paradyne Comsphere 3920Plus Installation And Operation Manual page 198

Comsphere 392 plus series
Hide thumbs Also See for Comsphere 3920Plus:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
S-Register
S41
Dial-Line Rate. Register determines the modem's data rate and modulation
scheme for operation on dial lines.
Register has the following values:
1 = 14,400 (V.32bis)
2 = 12,000(V.32bis)
3 = 9600 (V.32bis)
4 = 7200 (V.32bis)
5 = 4800 (V.32bis)
6 = 2400 (V.22bis)
7 = 1200 (V.22)
8 = 1200 (212A)
10 = 0–300 (V.21)
11 = 0–300 (103J)
12 = 1200/75 (V.23)
13 = 75/1200 (V.23)
18 = 600/75 (V.23)
19 = 75/600 (V.23)
20 = 19,200 (V.32 terbo)
21 = 16,800 (V.32 terbo)
22 = 33,600
23 = 31,200
24 = 28,800 (V.34)
25 = 26,400 (V.34)
26 = 24,000 (V.34)
27 = 21,600 (V.34)
28 = 19,200 (V.34)
29 = 16,800 (V.34)
30 = 14,400 (V.34)
31 = 12,000 (V34)
32 = 9600 (V34)
33 = 7200 (V34)
34 = 4800 (V34)
35 = 2400 (V34)
The factory setting is 28,800 (V.34).
S43
V.32bis Train. Register controls the modem's train time for V.32bis/V.32 mode.
Register has the following values:
0 = Long
1 = Short
The factory setting is Long.
5-18
Table 5-3
(3 of 12)
392x Plus S-Registers
Description
April 1995
DCP LCD
Command
Sequence
Configure\Edit\
Dial Line
Configure\Edit\
Dial Line
3920-A2-GN31-10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3921plus

Table of Contents