Cables - Paradyne Comsphere 3920Plus Installation And Operation Manual

Comsphere 392 plus series
Hide thumbs Also See for Comsphere 3920Plus:
Table of Contents

Advertisement

3920Plus
E, G
3920Plus F

Cables

Cable 1
Cable 2
Cable 3
Cable 4
3920-A2-GN31-10
Use TMp Tributary template default configuration options with the following
exceptions:
Port2 MSD
RTS Action
Auto Dial Back
Auto Dial Standby
Dial Line Rate
Use TMp Tributary template default configuration options with the following
exceptions:.
RTS Action
Auto Dial Back
Auto Dial Standby
Dial Line Rate
Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug)
connector at one end to attach to the modem. Attach this to the connector labeled
DTE1, 2, 3, or 4.
Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is
supplied with the modem). Attach this to the connector labeled LEASED.
Use part number 818-2759-0111 or an equivalent customer-supplied,
EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to
attach to the modems. (See Appendix C for pin assignments.)
Use part number 125-0067-0031 (a 6-position, 4-wire modular cord that is
supplied with the modem). Attach this to the connector labeled DIAL.
April 1995
Set to Enable.
Set to Sim_Cntl_Car.
Set to Enable.
Set to Adv 15min.
Set to 14400(V34).
Set to Sim_Cntl_Car.
Set to Enable.
Set to Adv 15min.
Set to 14400(V34).
Sample Configurations
G-17