COMSPHERE 392xPlus Modems
The message Started appears on the LCD and the Test LED lights.
The port field (for example, P1 for Port 1) displays the port that is currently selected. You may see
P1, P2, P3, or P4.
BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits
per block). BlksRcvd=xxxxxxx displays the total number of blocks of data received. Select Clear
to reset both block counters. When the mux is disabled, the message NoSync can appear as a value
for BlksErrd while the modem's receiver is synchronizing. The message OvrFlw can appear as the
value for BlksErrd if the counter overflows.
Press the
Press the
The Pattern test can be exited and reentered without restarting the test. The BlksErrd and BlksRcvd
continue counting.
If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the
test. If it is disabled, the test operates until aborted. For more information on the Test Timeout
configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the
Top-Level menu, press the
3-62
Test:P1:Pattern
Started
F1
F2
F3
Test:Pattern
>
BlksErrd=xxxxxxx
F3
F1
F2
key to display BlksRcvd=xxxxxxx, number of blocks of data received.
key to display Clear. Select Clear to reset the block counters.
key.
April 1995
key. To exit and return to the
3920-A2-GN31-10