Paradyne Comsphere 3920Plus Installation And Operation Manual page 160

Comsphere 392 plus series
Hide thumbs Also See for Comsphere 3920Plus:
Table of Contents

Advertisement

DCP Configuration
Table 4-9
(3 of 4)
A
Line Dialer Configuration Options — Mux DISABLED
Long Space Disc: Enable
Nxt Enable Disable
Long Space Disconnect. Determines the modem's response to a continuous spacing condition sent from the remote
modem before it goes on-hook. Issuing a long space is one method of disconnecting a call.
Enable – Modem disconnects if it receives a continuous space from the DTE. For modulations lower than 4800 bps, the
modem's transmitter will transmit 4 seconds of long space upon a disconnect.
Disable – Modem does not disconnect if it receives a continuous space from the DTE. Modem will not transmit a long
space disconnect.
The AT command for Disable is Y0.
The AT command for Enable is Y1.
No Carrier Disc: 2sec
Nxt 2sec Disable 5sec 10sec 20sec
No Carrier Disconnect. If the modem no longer receives carrier from the remote modem, it disconnects the call. This
configuration option determines how long carrier is OFF before the modem disconnects. Loss of carrier is one method of
disconnecting a call.
2, 5, 10, 20 sec – Modem disconnects if carrier turns OFF for more than 2 seconds, 5 seconds, 10 seconds, or
20 seconds.
Disable – Modem does not disconnect if carrier turns OFF.
NOTE: The range of allowable values may be restricted in some countries.
The AT command is S-Register S10= n , where n is 255 for Disable or 0 to 254 in 0.1 second increments for Enable.
No Data Disc: Disable
Nxt Disable 10min 30min 60min
No Data Disconnect. Forces the modem to disconnect if no data is transmitted and received within a specified amount
of time.
Disable – Modem remains connected despite the lack of data flow.
10, 30, 60 min – Modem disconnects if data is not received and transmitted within 10-minute, 30-minute, or 60-minute
intervals.
NOTE: The factory default value is country dependent.
The AT command for Enable is \T n , where n is from 1 minute to 255 minutes.
The AT command for Disable is \T0.