Paradyne Comsphere 3920Plus Installation And Operation Manual page 203

Comsphere 392 plus series
Hide thumbs Also See for Comsphere 3920Plus:
Table of Contents

Advertisement

S-Register
S66
NMS Call Messages. Register determines if the modem sends information
regarding status (Call Progress) and/or sends summarized call statistics (Call
Connect) to the 6700 Series Network Management System (NMS).
Register has the following values:
0 = Call Connect & Progress
1 = Disable
2 = Call Connect Only
3 = Call Progress Only
The factory setting is Call Connect & Progress.
S67
Directory Location 1 Callback. Register determines if the modem uses the
single number callback function.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
S69
Make Busy Via DTR. Register determines if the modem goes off-hook (busy)
when DTR is OFF.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
S70
V.27bis Train. Register controls the train time for V.27bis operation.
Register has the following values:
0 = Short
1 = Long
The factory setting is Short.
S71
XTXC Clamps TXC. Register allows the modem's TXC output to be clamped
off when TX Clock Source is configured for External.
Register has the following values:
0 = Enable
1 = Disable
The factory setting is Enable.
S72
RTS Antistreaming. Register determines the antistreaming operation of the
modem.
Register has the following values:
0 = Disable
1 = 10 sec
2 = 30 sec
3 = 1 min
4 = 2 min
5 = 3 min
6 = 5 min
The factory setting is Disable.
3920-A2-GN31-10
Table 5-3
(8 of 12)
392x Plus S-Registers
Description
April 1995
AT Command Set and S-Registers
DCP LCD
Command
Sequence
Configure\Edit\
Misc
Configure\Edit\
Misc
Configure\Edit\
Line Dialer
Configure\Edit\
Leased Line
Configure\Edit\
DTE Interface
Configure\Edit\
DTE Interface
5-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3921plus

Table of Contents