Selection of Operation upon Digital Operator Disconnection

If the Inverter detects disconnection of the Digital Operator (= communication with the Digital
Operator has been disrupted for 5 s or more), the Inverter operation conforms to the setting of
Selection of Operation on Digital Operator Disconnection (b165).
Parameter
No.
b165

Initial Screen Selection (Screen at Power-ON)

The Digital Operator screen to be displayed at power-on can be selected from among the
following: (By factory default, "001 (d001)" is selected.)
Main Built-in Digital Operator
Parameter
No.
b038
*1.If "000" is selected and then the power is turned off without changing the setting, this item (b038) will
be displayed the next time the power is turned on.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Function name
00: Trip (E40. )
01: Trip after deceleration stop (E40. )
Selection of
Operation on
02: Ignore
Digital Operator
Disconnection
03: Free-run stop
04: Deceleration stop
Function name
Data
000
001
002
Initial Screen
Selection
003
:
060
201
202
5-7 Digital Operator/Operation Functions
Data
Description (Digital Operator)
Screen on which the Enter key
was pressed last (All items other
than d*** and F001 are
*1
parameters.)
d001 (Output Frequency Monitor)
d002 (Output Current Monitor)
d003 (Rotation Direction Monitor)
: (Each item corresponds to d***.)
d060 (Inverter Mode Monitor)
F001 (Output Frequency Setting)
Do not set
Default
Unit
setting
02
Default
Unit
setting
001
5-86
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents