Register
Function name
No.
242Ah
to
Not used
2501h
2502h Motor Parameter 2
2503h Motor Capacity 2
2504h Motor Pole Number 2
2505h
Speed Response 2
2506h
2507h Stabilization Parameter 2
2508h
to
Reserved
2515h
2516h Motor 2 Parameter R1
2517h Reserved
2518h Motor 2 Parameter R2
2519h Reserved
251Ah Motor 2 Parameter L
251Bh Reserved
251Ch Motor 2 Parameter Io
251Dh
Motor 2 Parameter J
251Eh
251Fh
to
Reserved
2524h
Motor 2 Parameter R1
2525h
(Auto-tuning Data)
2526h Reserved
Motor 2 Parameter R2
2527h
(Auto-tuning Data)
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
6-8 List of Modbus Communication (Modbus-RTU) Data
Parameter
R/W
No.
−
−
H202
R/W
H203
R/W
H204
R/W
H205
R/W
(HIGH)
H205
R/W
(LOW)
H206
R/W 0 to 255
−
−
H220
R/W 1 to 65530
−
−
H221
R/W 1 to 65530
−
−
H222
R/W 1 to 65530
−
−
H223
R/W 1 to 65530
H224
R/W
(HIGH)
H224
R/W
(LOW)
−
−
H230
R/W 1 to 65530
−
−
H231
R/W 1 to 65530
Monitor and setting
parameters
Inaccessible
00: Standard motor
parameter
02: Auto-tuning data
00: 0.1
01: 0.2
02: 0.4
03: 0.55
04: 0.75
05: 1.1
06: 1.5
07: 2.2
08: 3.0
09: 3.7
10: 4.0
11: 5.5
00: 2P
01: 4P
02: 6P
03: 8P
04: 10P
1 to 1000
−
−
−
−
1 to 9999000
−
−
Data
Page
resolution
−
−
−
−
5-145
−
1 [%]
6
1
5-81
−
−
0.001 [Ω]
5-145
−
−
0.001 [Ω]
5-145
−
−
0.01 [mH]
5-145
−
−
0.01 [A]
5-145
0.01
5-145
−
−
0.001 [Ω]
5-145
−
−
0.001 [Ω]
5-145
6-72