2-2 Wiring

Connection Diagram

ELB
Single-phase
3-phase
power
supply
If any external source-logic
output equipment or power
supply is used, refer to
"Connection to
Programmable Controllers
(PLC)" on page 2-22.
Multi-function
input
(7 contact
points)
10 VDC power
2 kΩ or more
supply (7 mA Max.)
Analog voltage input
0 to 10 V (10 bits)
Analog current input
4 to 20 mA (10 bits)
Pulse input
5 to 24 VDC
(32 kHz Max.)
Analog voltage
output 0 to 10 V
Pulse output
0 to 10 VDC
(32 kHz Max.)
Note 1: Connect a single-phase 200 V AC input to terminals L1 and N.
Note 2: Factory default settings for relay output are NC contact for MA and NO contact for MB.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
MC
R/L1
S/L2
T/L3
24VDC
Shorting
P24
P24
bar
PSC
SC
S7/EB
S6
S5/TH
S4/GS2
S3/GS1
S2
S1
FS
FV
FI
RP
(10 bits)
AM
MP
SC
Class D (200 V class)
Class C (400 V class)
U/T1
M
V/T2
W/T3
Motor
Shorting bar
DC reactor
+1
To connect the DC
reactor, remove
P/+2
the shorting bar.
RB
N/−
Braking Resistor*1
MC
MA
Multi-function
relay output
MB
P2
Multi-function output
P1/EDM
(2 terminals)
PC
RS+
Serial communication port
(RS-485/Modbus-RTU)
RS−
When using a Regenerative Braking Unit
Regenerative
P/+2
Braking Resistor*1
Braking Unit*1
RB
P
P
N
RB
N/
*1 Option

2-2 Wiring

2
2-6

Hide quick links: