5-12 Simple Position Control Function

Zero Return Function

This function performs two types of zero return operations according to Zero Return Mode
(P068).
Zero return starts when the Zero return start signal (70: ORG) turns ON. When zero return is
complete, the current position is cleared (= 0).
Select the zero return direction in Zero Return Direction Selection (P069).
If zero return is not performed, the Inverter performs position control with the position at power-
on defined as the origin.
Parameter
5
C001 to C007
Zero Return Mode 1 (P068 = 00)
ORG input
ORL input
Output
frequency
(1) Accelerate until the zero return mode 1 frequency (speed) according to the acceleration time.
(2) Operate at the zero return mode 1 frequency (speed).
(3) Apply DC injection braking (DB) the moment an ORL signal is input.
5-165
Function name
No.
P068
Zero Return Mode
Zero Return
P069
Direction Selection
Zero Return Mode 1
P070
Frequency
Zero Return Mode 2
P071
Frequency
Multi-function Input
Selection
(2)
(1)
Data
00: Zero return mode 1
01: Zero return mode 2
00: Forward side
01: Reverse side
0.00 to 10.00
0.00 to 400.0
69: ORL (Zero return limit signal)
70: ORG (Zero return startup signal)
ON
ON
Zero Return Mode 1 Frequency (P070)
(3) DB
Position
Zero
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Default
Unit
setting
00
01
5.00
Hz
5.00
Hz