5-2 Basic Functions
Parameter
H002/H202
Take note that the following multi-function input terminals cannot be selected in the light load
mode:
40: TL
41: TRQ1
42: TRQ1
5
52: ATR

Frequency Reference Selection and Output Frequency Setting

Select the method of the frequency reference.
Since multi-step speed operation (in which a combination pattern of input terminals is used to
specify the speed) is given priority over Frequency Reference Selection (A001), A001 need not
be set. Only when all multi-step speed inputs are OFF and therefore 0th is specified, the
frequency conforms to the setting of A001.
5-15
Function name
No.
Overtorque Level
C056
(Reverse Regeneration)
Overtorque Level
C057
(Reverse Power Running)
Overtorque Level
C058
(Forward Regeneration)
Overtorque/Undertorque Signal
C059
Output Mode Selection
Auto-tuning Selection
H001
Motor Parameter 1/2
Multi-function input terminals
Torque limit enabled/disabled
Torque limit switching 1
Torque limit switching 2
Torque reference input permission
Parameter
Function name
No.
P034
Torque Reference Setting
P036
Torque Bias Mode
P037
Torque Bias Value
P038
Torque Bias Polarity Selection
Speed Limit Value in Torque
P039
Control (forward)
Speed Limit Value in Torque
P040
Control (reverse)
Multi-function output/relay terminals
07: OTQ
Overtorque/undertorque
10: TRQ
During torque limit
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)