Omron SYSDRIVE MX2 SERIES User Manual page 210

Multi-function compact inverter
Hide thumbs Also See for SYSDRIVE MX2 SERIES:
Table of Contents

Advertisement

5-8 Restart Functions
The major parameters relating to frequency matching restart and frequency pull-in restart are
listed below.
For details, refer to the section on each function.
Classification
Common
Frequency
matching
restart
Frequency
pull-in restart
5
Power supply
Output current
Inverter output
frequency
Motor rotation speed
5-95
Parameter
Function name
No.
Restart Standby
b003
Matching Lower
b007
Limit Frequency
Frequency Pull-in
b028
Frequency Pull-in
b029
Restart Parameter
b030
Frequency Pull-in
Restart Selection
FW input
(forward)
0.3 to 100.0
Time
Time until restart
0.00 to 400.0 (1000.)
Frequency
If the frequency drops to b007
or below during the motor free
run, the Inverter restarts at 0
Setting
Hz.
0.20 × Rated current to 2.00 ×
Rated current
Restart Level
0.10 to 30.00
Frequency reduction time
00: Frequency at interruption
Starting
Frequency at
01: Maximun frequency
02: Set frequency
Decelerates according to b029.
b028
Frequency selected in b030
b003
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Default
Data
setting
1.0
0.00
Inverter
rated
current
0.50
00
Unit
s
Hz
A
s

Hide quick links:

Advertisement

Table of Contents
loading