Parameter No. Function name
C001
C002
4
C003
C004
C005
C006
C007
4-25
Monitor or data range
00: FW (Forward)
Multi-function
01: RV (Reverse)
Input 1
02: CF1 (Multi-step speed 1)
*1
Selection
03: CF2 (Multi-step speed 2)
04: CF3 (Multi-step speed 3)
05: CF4 (Multi-step speed 4)
06: JG (Jogging)
07: DB (External DC injection braking)
08: SET (Motor 2 control)
09: 2CH (2-step acceleration/deceleration)
11: FRS (Free-run stop)
Multi-function
12: EXT (External trip)
13: USP (USP function)
Input 2
14: CS (Commercial switch)
Selection
15: SFT (Soft lock)
16: FV/FI (Analog input switch)
18: RS (Reset)
19: TH (PTC thermistor thermal protection)
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID disabled)
Multi-function
24: PIDC (PID integral reset)
Input 3
27: UP (UP/DWN function accelerated)
*1
Selection
28: DWN (UP/DWN function decelerated)
29: UDC (UP/DWN function data clear)
31: OPE (Forced operator)
32: SF1 (Multi-step speed bit 1)
33: SF2 (Multi-step speed bit 2)
34: SF3 (Multi-step speed bit 3)
35: SF4 (Multi-step speed bit 4)
36: SF5 (Multi-step speed bit 5)
37: SF6 (Multi-step speed bit 6)
Multi-function
38: SF7 (Multi-step speed bit 7)
Input 4
39: OLR (Overload limit switching)
*1
Selection
40: TL (Torque limit enabled/disabled)
41: TRQ1 (Torque limit switching 1)
42: TRQ2 (Torque limit switching 2)
44: BOK (Brake confirmation)
46: LAC (LAD cancel)
47: PCLR (Position deviation clear)
50: ADD (Frequency addition)
51: F-TM (Forced terminal block)
Multi-function
52: ATR (Torque reference input permission)
Input 5
53: KHC (Integrated power clear)
56: Reserved.
Selection
57: Reserved.
58: Reserved.
59: Reserved.
60: Reserved.
61: Reserved.
62: Reserved.
65: AHD (Analog command held)
66: CP1 (Position command selection 1)
Multi-function
67: CP2 (Position command selection 2)
Input 6
68: CP3 (Position command selection 3)
Selection
69: ORL (Zero return limit signal)
70: ORG (Zero return startup signal)
73: SPD (Speed/position switching)
77: GS1 (GS1 input (C003 only))
78: GS2 (GS2 input (C004 only))
81: 485 (Start co-inverter communication)
82: Reserved.
83: HLD (Retain output frequency)
Multi-function
84: ROK (Permission of RUN command)
85: EB (Rotation direction detection (C007 only))
Input 7
86: DISP (Display fixed)
Selection
no: NO (Not assigned)
Data can
Default
be set
Set data
setting
during
RUN
00
(FW)
01
(RV)
18 (RS)
12
(EXT)
02
(CF1)
03
(CF2)
06 (JG)
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Data can be
changed
Unit Page
during RUN
no
yes
no
yes
no
yes
no
yes
5-29
no
yes
no
yes
no
yes