7-1 Error Display and Remedial Actions
Brake error
Emergency
shutoff
Overload
protection in a
low speed
range
Poor Digital
Operator
connection
Modbus
communication
(Modbus-RTU)
error
7
Internal data
error
Encoder
disconnection
Excess speed A trip will occur if the motor rotation
Positioning
error
Position control
range trip
*1. It cannot be reset with STOP/RESET keys. Perform a reset by reconnecting the power or operating
the RS (reset) terminal.
7-5
Name
Description
A trip will occur if brake ON/OFF cannot
be confirmed within the Brake
Confirmation Wait Time (b124) after the
Inverter has issued a brake release
output, provided that the Brake Control
function is enabled (b120 = 01).
*1
If an overload occurs in the extremely
low speed range of 0.2 Hz or below, it
will be detected by the built-in
electronic thermal of the Inverter and a
trip will occur. (However, the error
history may indicate a high frequency).
A trip will occur upon error in the
communication with, or disconnection
of, the external Digital Operator or LCD
Operator.
A trip will occur upon timeout if the
communication error selection is set to
tripping (C076 = 00).
A trip will occur upon detection of
encoder disconnection or poor
connection.
speed exceeds the "maximum
frequency × Overspeed Error Detection
Level (P026)" or above.
A trip will occur if the current position
deviation against the position reference
value exceeds 1,000,000 pulses during
simple position control.
A trip will occur if the current position
exceeds the Position Range Setting
(P072, P073) during simple position
control.
Error
Check point and remedy
code
E36.
Is the brake ON/OFF
function working?
→Check the brake.
Is the set time for b124 too
short?
→Increase b124 .
Has the brake confirmation
signal been input?
→Check the wiring.
E37.
E38.
Is the load too large?
→Decrease the load rate.
E40.
Is there any communication
error?
→Check/replace the
cable.
(Note that if b165 is set
to "02," this error will
not be detected).
E41.
Is the communication
speed correct?
→Check the setting.
Is the wiring distance
appropriate?
→Check the
communication wiring.
Has disconnection
occurred?
→Check the wiring.
E43. to
E45.
E50. to
E69.
E80.
E81.
E82.
E83.