Omron SYSDRIVE MX2 SERIES User Manual page 317

Multi-function compact inverter
Hide thumbs Also See for SYSDRIVE MX2 SERIES:
Table of Contents

Advertisement

Parameter
No.
Recipient Station
Number of All Stations
P144
in Co-inverter
Communication 2
Recipient Register of
All Stations in Co-
P145
inverter
Communication 2
Sender Register of All
P146
Stations in Co-inverter
Communication 2
Recipient Station
Number of All Stations
P147
in Co-inverter
Communication 3
Recipient Register of
All Stations in Co-
P148
inverter
Communication 3
Sender Register of All
P149
Stations in Co-inverter
Communication 3
Recipient Station
Number of All Stations
P150
in Co-inverter
Communication 4
Recipient Register of
All Stations in Co-
P151
inverter
Communication 4
Sender Register of All
P152
Stations in Co-inverter
Communication 4
Recipient Station
Number of All Stations
P153
in Co-inverter
Communication 5
Recipient Register of
P154
All Stations Co-inverter
Communication 5
Sender Register of All
P155
Stations in Co-inverter
Communication 5
C001 to
Multi-function Input
C007
Selection
*1. The details of the setting destination are as follows.
ALL: Set for all connected Inverters.
A: Set only for the Management Inverter (Station No. 01).
B: Set for Inverters other than the Management Inverter (Station No. 01).
M: Set for the Inverter whose station number is specified in C098 or C099 (= Master Inverter).
*2. Even when C072 and C096 to C100 of the Management Inverter are changed, the changes will not be
reflected until the power is reconnected or a reset is performed (by turning the RS terminal ON and
then turning it OFF). Changes made to the same parameters of other Inverters are immediately
reflected.
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Function name
1. to 247.
0000 to FFFF Hex
0000 to FFFF Hex
1. to 247.
0000 to FFFF Hex
0000 to FFFF Hex
1. to 247.
0000 to FFFF Hex
0000 to FFFF Hex
1. to 247.
0000 to FFFF Hex
0000 to FFFF Hex
81: 485 (inverter communication
start)
6-7 Co-Inverter Communication
Default
Data
setting
2.
0000
0000
3.
0000
0000
4.
0000
0000
5.
0000
0000
Setting
Unit
*1
destination
M
M
M
M
M
M
M
6
M
M
M
M
M
A
6-24

Hide quick links:

Advertisement

Table of Contents
loading