6-8 List of Modbus Communication (Modbus-RTU) Data
Register
No.
12A7h
to
12AEh
12AFh
12B0h
12B1h
12B2h Reserved
12B3h
6
12B4h
12B5h
12B6h
to
12B8h
12B9h
12BAh
12BBh
12BCh
12BDh
12BEh
12BFh Deceleration Stop Time
12C0h
12C1h
12C2h
6-45
Parameter
Function name
Reserved
Operation Frequency
Selection 1
Operation Frequency
Selection 2
Operation Function
Operator Selection
Frequency Addition
Amount Setting
Frequency Addition Sign
Selection
Reserved
EL-S Shape Acceleration
Curve Ratio 1
EL-S Shape Acceleration
Curve Ratio 2
EL-S Shape Deceleration
Curve Ratio 1
EL-S Shape Deceleration
Curve Ratio 2
Deceleration Stop
Frequency
PID Sleep Function
Operation Level
PID Sleep Operation
Delay Time
Monitor and setting
R/W
No.
parameters
00: Digital Operator
01: Volume
02: FV (voltage) input
03: FI (current) input
A141
R/W
04: Modbus communication
(Modbus-RTU)
05: Do not set.
07: Pulse train frequency
00: Digital Operator
01: Volume
02: FV (voltage) input
03: FI (current) input
A142
R/W
04: Modbus communication
(Modbus-RTU)
05: Do not set.
07: Pulse train frequency
00: Addition (A141 + A142)
01: Subtraction (A141 −
A143
R/W
A142)
02: Multiplication (A141 ×
A142)
A145
R/W
(HIGH)
0 to 40000 (100000)
A145
R/W
(LOW)
00: Frequency reference +
A145
A146
R/W
01: Frequency reference −
A145
A150
R/W 0 to 50
A151
R/W 0 to 50
A152
R/W 0 to 50
A153
R/W 0 to 50
A154
(HIGH)
R/W 0 to 40000 (100000)
A154
(LOW)
A155
R/W 0 to 600
A156
(HIGH)
R/W 0 to 40000 (100000)
A156
(LOW)
A157
R/W 0 to 255
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
Data
Page
resolution
5-70
0.01 [Hz]
5-71
1 [%]
1 [%]
5-68
1 [%]
1 [%]
0.01 [Hz]
5-62
0.1 [s]
0.01 [Hz]
5-73
0.1 [s]